Simon optimal two stage design
http://www.cancer.unc.edu/biostatistics/program/ivanova/SimonsTwoStageDesign.aspx Webb1 juli 2024 · Compared with the Gehan two-stage design, the Simon two-stage design has the advantage of being able to determine an early termination of trials when no or low anti-tumor activities...
Simon optimal two stage design
Did you know?
WebbOptimum Designs Simon (1989) defines two optimum designs. The first is the minimax design which is the design with the smallest N that obeys both error rate constraints. … Webb22 feb. 2024 · In early phase clinical studies in oncology, Simon's two-stage designs are widely used. The trial design could be made more efficient by stopping early in the …
Webb20 maj 2024 · In both Simon’s and Fleming’s two-stage designs, the maximum sample size of admissible design is smaller than optimal design but larger than minimax design. … Webb第1段階 第2段階 ※Simonの最適法の特徴 n1,n2,a1,aは帰無仮説のもとで,平均的に 必要な患者数が最小になるように算出 2010/07/26 SASユーザー総会2010 10 / 26 SimonのMinimax法 薬剤が無効な場合に早期中止を判断するための2段階デザイン
Webb28 juli 2024 · Since Rich Simon proposed optimal design and minimax design for two-stage phase II trials in 1986, either of them has been chosen for most of phase II clinical trials. When designing a phase II trial, however, clinical trialists almost always question which design to select. WebbSimon's Two-Stage Design. PID:961; v1.0.2.0; Last Updated: 04/15/2024. Liangcai Zhang 1,2 and Ying Yuan 1,2. 1 Department of Statistics, Rice University, Houston, TX 77005. ... Simon R (1989). Optimal two-stage designs for phase II …
Webb1 mars 1989 · This paper presents two-stage designs that are optimal in the sense that the expected sample size is minimized if the regimen has low activity subject to constraints upon the size of the type 1 and type 2 errors. Two-stage designs which minimize the maximum sample size are also determined.
WebbSimon两阶段设计常用于肿瘤药物单臂两阶段试验,具有节省样本量,早期发现试验无效及时终止试验,避免受试者接受无效治疗,节省时间和成本,更加符合伦理要求的特点。 phone link app crashesWebb2 juli 2024 · Modified Simon's minimax and optimal two-stage designs for single-arm phase II cancer clinical trials. Simon's two-stage design and the admissible two-stage … how do you power on iphone xrWebbSimon's Two-Stage design This program generates Simon's optimal two-stage designs (Simon, 1989) and admissible designs from Jung et al. (2004) for Phase II single arm … phone link app featuresWebbtwo-stage design that is optimal in the sense that the expected sample size is minimized if the regimen has low activity subject to constraints upon the size of the type 1 and type 2 errors. Two-stage designs which minimize the maximum sample size are also determined. simon2stage(p0, pa, alpha, beta, eps =0, N_min, N_max, int =0, phone link app file locationWebb1 mars 1989 · This paper presents two-stage designs that are optimal in the sense that the expected sample size is minimized if the regimen has low activity subject to constraints … how do you power reset your laptopWebb1 mars 1989 · When Optimal Two-Stage Designs the drug has substantial activity (--pi) there is often interest in studying additional patients in order to estimate the proportion, … how do you practice being inclusiveWebb15 apr. 2024 · Design parameters. Type I error rate, α (one-sided): Power, 1-β : Unpromising response rate, p0 (null hypothesis) Desirable response rate, p1 (alternative hypothesis) … how do you power the cloning chamber ark