WebThe efficiency of an electric motor is expressed as a percentage. It indicates how much input electrical energy is converted to output mechanical energy. You can see the nominal efficiency for this motor is 95.8%. The higher the percentage means the more efficiently the motor converts incoming electrical power to mechanical horsepower. http://lancet.mit.edu/motors/motors2.html
Reading a motor curve
Did you know?
WebFeb 20, 2024 · To turn this into feet we need to use the conversion factor of 2.31 Ft/psi. By multiplying the differences in the gauges by 2.31 we get the head pressure of 92.4 Feet of Head. You can use this pump differential pressure to derive at the pumps total head and then apply the results to the pump curve. A motor / gear motor performance curve conveys five specific parameters; speed, torque, current draw, power and efficiency. The overall performance data will illustrate the optimal conditions the motor should operate at as well as its limitations. This information can be used to determine if the motor will be … See more Now that we have covered the basics, you can begin to understand what the lines and numbers represent. The performance curve below is a more detailed performance representation for a typical dc gear motor. We will … See more Electric motorshave two types of usage which are defined by torque capacity in which they are operating at. These ranges are meant to depict the overall safe operating limits of the … See more We hope that this explanation has helped you get more familiar with motor and gear motor performance curves. Not all vendors or manufacturers will offer all of the motor data so if a certain parameter is missing, please … See more
WebReading BHp Curve. 0 0.5 1 1.5 2 2.5 3 3.5 0 5 10 15 20 25 30 35 40 45 CFM x 100 Pressure 700 RPM. 350 RPM. Operating Point. at 700 RP. M Operating Point. at 350 RP. M. Varying Operating Points. Large change in Ps . Small change in CFM. Small change in Ps . Large change in CFM. CFM. Ps. Selecting Point of Operation. Ps. Operating Point. Optimum WebDec 26, 2016 · When the percent locked rotor torque is close to or below full load torque, closer scrutiny should be applied. In the recent past, many speed torque curves have …
WebFeb 2, 2024 · The curve represents actually a lot of functioning points associated to the motor. For example, a motor at 12 V with a given load of 5 mN.m will have a given speed … WebDec 17, 2011 · Consider a centrifugal pump operating at 4,000-gpm and producing 300-ft of head at 1800-rpm. According to its curve (see Figure 1 below), pump efficiency is 82 percent. This happens to be at the best efficiency point (BEP) point, but, in general, the same logic would apply to any operating point.
WebFirst, the red line on the left hand side of the pump curve is the Minimum Continuous Stable Flow (MCSF) line. This is the point beyond which the pump manufacturer has determined the pump should not be allowed to …
WebDec 6, 2013 · Fig. 1: The graph shows motor performance at an initial temperature of 25°C. Fig. 2: A comparison of motor performance at the initial 25°C level and at an elevated … flutter textfield widthWebDec 6, 2013 · Fig. 1: The graph shows motor performance at an initial temperature of 25°C. Fig. 2: A comparison of motor performance at the initial 25°C level and at an elevated temperature of 125°C shows a marked decrease in current and torque. Fig. 3: This graph shows how the maximum power is impacted by elevated temperature. greenheck roof mounted fan iomWebGenerally speaking, curves which indicate RPM to be between 3400 and 3600 RPM are used for all two pole (3600 RPM nominal speed) motors applications. Return to Table of Contents Return to Top of Lesson Two Flow The pump’s flow range is shown along the bottom of the performance curve. greenheck saltillo assemblyWebTo understand centrifugal pump performance, we need to understand the pump curve. This video explains how to read these charts so we can understand how to assess or improve … flutter text field widthWebJan 15, 2024 · In Fig. 2, a positive displacement pump curve shows the influence of viscosity on slip with a correction chart. With changes in viscosity and pressure, slip correction … flutter textfield submit on enterWebJun 19, 2024 · Reading Thermal Damage Curves. Thermal damage curves are plots that provide information about acceleration times, operational … greenheck rve catalogWebMay 13, 2015 · You are considering it from an electrical engineering perspective. Speed vs torque. It's more a digital motor with a rotor position that can be easily controlled (read head on floppy drives). It is a brushless motor and its strongest torque (traction or holding) occurs when the coils are energized. They have fractional hp ratings (>34.3 mN·m). greenheck rooftop exhaust fans